Aquarius provides a wide range of parts and accessories to compliment your controller. A summary and description of some of these can be found below.
- Sensors | Probes
- Reagents | Buffer Solutions
- Pumps
- Solenoids | Relays
- Water Meters
- Brominators
- Web | Network Connectivity
TARAline CS4MA-200 Free Chlorine Sensor
This membrane sensor is made for the measurement of Free Chlorine in water. *Reduced dependence on pH.
Specifications:
- Measurement System: Membrane covered, amperometric potentiostatic 3-electrode system
- Reference: ECS2.1/GEL
- pH Range: pH 4 – pH 9
- Measurement Range: 0.5ppm to 200ppm (CS4MA-200)
- Resolution: 0.1ppm (CS4MA-200)
- Working Temp: 0°C to +45°C (in water)
- Max Pressure: 3 Bar (retaining ring), 0.5 Bar (no retaining ring)
- Flow Rate: Approx. 15-30 l/h (33 – 66 cm/s) in TARAflow FLC
- Output: Analog 4-20mA
- Dimensions: 190mm L (5-pole-M12)
SZ283 Cl2, O3 and ClO2 Potentiostatic Electrode
This sensor is made for the measurement of Free Chlorine, Chlorine Dioxide and Dissolved Ozone in water.
Specifications:
- Electrodes: 2 Platinum Rings
- Reference: Gel with Annular Junction
- Body: Glass
- Cable: 3m
- Max Pressure: 10 bar at 20°C
- Dimensions: 110x12mm
TARAline CP4.0 Total Chlorine Sensor
This membrane sensor is made for the measurement of Total Chlorine (free chlorine + combined chlorine) in water. *Reduced dependence on pH.
Specifications:
- Measurement System: Membrane covered, amperometric potentiostatic 3-electrode system
- Reference: ECP1.4/GEL
- pH Range: pH 4 – pH 12
- Measurement Range: 0.05ppm to 10.0ppm (CP4.0MA10)
- Resolution: 0.01ppm (CP4.0MA10)
- Working Temp: 0°C to +45°C (in water)
- Max Pressure: 3 Bar (retaining ring), 0.5 Bar (no retaining ring)
- Flow Rate: Approx. 15-30 l/h (33 – 66 cm/s) in TARAflow FLC
- Output: Analog 4-20mA
- Dimensions: 190mm L (5-pole-M12)
ST-730 Series Inline Turbidity Probes
These series of probes are more robust and tolerant to fouling, particulate and air bubble challenges compared to alternative turbidity meters designed for relatively clean water applications. Isolated 4-20mA analogue and RS-485 digital outputs.
Applications:
- Industrial Process & Cooling Water
- Fresh | Brackish | Sea Water (CPVC versions only)
- Raw | Influent Water
- Wastewater Effluent
- Surface Water | Storm Water
Models:
- ST-730
– 0-100 NTU Range | 0.1 NTU Resolution | ≤ 100psi
- ST-730B
– 0-1,000 NTU Range | 1.0 NTU Resolution | ≤ 100psi
- ST-730SS
– 0-100 NTU Range | 0.1 NTU Resolution | ≤ 290psi
- ST-731
– 0-10 NTU Range | 0.05 NTU Resolution | ≤ 100psi
- ST-735
– 0-10,000 NTU Range | 10.0 NTU Resolution | ≤ 100psi
Aquarius Technologies pH / ORP Probe
Combination pH / ORP probes with built in Ground reference.
SZ283 Cl2, O3 and ClO2 Potentiostatic Electrode
This sensor is made for the measurement of Free Chlorine, Chlorine Dioxide and Dissolved Ozone in water.
Specifications:
- Electrodes: 2 Platinum Rings
- Reference: Gel with Annular Junction
- Body: Glass
- Cable: 3m
- Max Pressure: 10 bar at 20°C
- Dimensions: 110x12mm
Low Level | Empty Tank Alarms
- Tank Alarm (Small): Adjustable to 500mm height with 3m pump tube & lead – 1 required per tank.
- Tank Alarm (Large): Adjustable to 1000mm height with 5m pump tube & lead – 1 required per tank.
TARAflow FLC-3 Flow Cell
Flow Cell for Membrane Sensor (High Temp). Rated @ 70°C | 800kPa
AS4250
Combination pH Buffer Solution 4.01 + ORP Calibration Solution 250mV – 250 mls
AS7086
Combination pH Buffer Solution 7.01 + ORP Calibration Solution 86mV – 250 mls
AS9500
Electrode Cleaning Solution for Removal of Inorganic Deposits on Electrodes – 250ml
Aquarius Technologies Peristaltic Pumps
Powerful, robust and reliable peristaltic dosing pumps.
- AP Peri1 : Peristaltic Pump rated @ 1.0 l/hr with 3pin plug
- AP Peri3 : Peristaltic Pump rated @ 3.0 l/hr with 3pin plug
Athena AM3 Pulse Pump
Dosing pump with option of receiving external digital signal (pulse emitter water meter) or an analogue signal 4-20 mA. Manual flow regulation 0->100%.
- Flow Rate: 10 l/hr
- Max Pressure: 1,000 kPa
- Strokes/Min: 300
- Power Consumption: 40 watt
- Weight: 4Kg
- IP Rating: IP65
Athena AM4 Pulse Pump
Dosing pump with option of receiving external digital signal (pulse emitter water meter) or an analogue signal 4-20 mA. Manual flow regulation 0->100%.
- Flow Rate: 20 l/hr
- Max Pressure: 500 kPa
- Strokes/Min: 300
- Power Consumption: 40 watt
- Weight: 4Kg
- IP Rating: IP65
Olimpia Pulse Pumps
Variable + impulse electromagnetic dosing pumps.
- Olimpia OL.BB : rated 2.0L/h @ 700kPa | IP65
- Olimpia OL.BD : rated 5.0L/h @ 500kPa | IP65
CO2 Regulator with 240VAC Solenoid Control
- 0-35 Lit/min CO2 Regulator
- Dual Gauges – Tank | Outlet Pressure
- High Quality Gas Solenoid with AU 240VAC plug
- Brass Fittings
- Barbed Brass CO2 Outlet
Turbine Water Meters with Pulse Emitter (Reed Switch). Available in various sizes.
- RH1 Water Meter : Hot | Cold 15mm – Max Flow 5m3/h, 4 lmp/L
- RH2 Water Meter : Hot | Cold 20mm – Max Flow 5m3/h, 4 lmp/L
- RH3 Water Meter : Hot | Cold 25mm – Max Flow 7m3/h, 4 lmp/L
- RH4 Water Meter : Hot | Cold 40mm – Max Flow 20m3/h, 4 lmp/L
- RH5 Water Meter : Hot | Cold 50mm – Max Flow 30m3/h, 4 lmp/L
Pressure Rated Feeders for the Controlled Dissolution of BCDMH – Bromine Tablets or Briquettes 12kg | 25kg | 100kg capacity.
- BCD12 : 12kg capacity rated to 350 kPa. Internal manifold designed for erosion efficiency. *Requires 15mm Solenoid.
- BCD25 : 25kg capacity rated to 350 kPa. Internal manifold designed for erosion efficiency. *Requires 20mm Solenoid.
- BCD100 : 100kg capacity rated to 350 kPa. Internal manifold designed for erosion efficiency. *Requires 25mm Solenoid.
- Modem 4G 850 : Web communication bundle with 4G modem (Add Web Access). *Ultima models only.
- Modem 4G 900 : 4G modem – 900mhz to enable full web control capabilities | alarming – Overseas users only.
- Web Access : SIM Card and annual contract for using AquaReporter Web Portal (Cloud).
- WiFi Adapter : WiFi adapter replacement. *Ultima models only.
- Ethernet Adapter : Ethernet adapter replacement. *Ultima models only.
- BMS Board : PCB card to convert 8 signals to 4-20mA for BMS systems. *Ultima models only.
- Modbus Board : PCB card to enable Modbus capabilities to BMS|DDC systems. *Ultima models only.
- Sensors | Probes
-
Chlorine | Chloramine
TARAline CS4MA-200 Free Chlorine Sensor
This membrane sensor is made for the measurement of Free Chlorine in water. *Reduced dependence on pH.
Specifications:
- Measurement System: Membrane covered, amperometric potentiostatic 3-electrode system
- Reference: ECS2.1/GEL
- pH Range: pH 4 – pH 9
- Measurement Range: 0.5ppm to 200ppm (CS4MA-200)
- Resolution: 0.1ppm (CS4MA-200)
- Working Temp: 0°C to +45°C (in water)
- Max Pressure: 3 Bar (retaining ring), 0.5 Bar (no retaining ring)
- Flow Rate: Approx. 15-30 l/h (33 – 66 cm/s) in TARAflow FLC
- Output: Analog 4-20mA
- Dimensions: 190mm L (5-pole-M12)
SZ283 Cl2, O3 and ClO2 Potentiostatic Electrode
This sensor is made for the measurement of Free Chlorine, Chlorine Dioxide and Dissolved Ozone in water.
Specifications:
- Electrodes: 2 Platinum Rings
- Reference: Gel with Annular Junction
- Body: Glass
- Cable: 3m
- Max Pressure: 10 bar at 20°C
- Dimensions: 110x12mm
TARAline CP4.0 Total Chlorine Sensor
This membrane sensor is made for the measurement of Total Chlorine (free chlorine + combined chlorine) in water. *Reduced dependence on pH.
Specifications:
- Measurement System: Membrane covered, amperometric potentiostatic 3-electrode system
- Reference: ECP1.4/GEL
- pH Range: pH 4 – pH 12
- Measurement Range: 0.05ppm to 10.0ppm (CP4.0MA10)
- Resolution: 0.01ppm (CP4.0MA10)
- Working Temp: 0°C to +45°C (in water)
- Max Pressure: 3 Bar (retaining ring), 0.5 Bar (no retaining ring)
- Flow Rate: Approx. 15-30 l/h (33 – 66 cm/s) in TARAflow FLC
- Output: Analog 4-20mA
- Dimensions: 190mm L (5-pole-M12)
TurbidityST-730 Series Inline Turbidity Probes
These series of probes are more robust and tolerant to fouling, particulate and air bubble challenges compared to alternative turbidity meters designed for relatively clean water applications. Isolated 4-20mA analogue and RS-485 digital outputs.
Applications:
- Industrial Process & Cooling Water
- Fresh | Brackish | Sea Water (CPVC versions only)
- Raw | Influent Water
- Wastewater Effluent
- Surface Water | Storm Water
Models:
- ST-730
– 0-100 NTU Range | 0.1 NTU Resolution | ≤ 100psi
- ST-730B
– 0-1,000 NTU Range | 1.0 NTU Resolution | ≤ 100psi
- ST-730SS
– 0-100 NTU Range | 0.1 NTU Resolution | ≤ 290psi
- ST-731
– 0-10 NTU Range | 0.05 NTU Resolution | ≤ 100psi
- ST-735
– 0-10,000 NTU Range | 10.0 NTU Resolution | ≤ 100psi
CombinationAquarius Technologies pH / ORP Probe
Combination pH / ORP probes with built in Ground reference.
SZ283 Cl2, O3 and ClO2 Potentiostatic Electrode
This sensor is made for the measurement of Free Chlorine, Chlorine Dioxide and Dissolved Ozone in water.
Specifications:
- Electrodes: 2 Platinum Rings
- Reference: Gel with Annular Junction
- Body: Glass
- Cable: 3m
- Max Pressure: 10 bar at 20°C
- Dimensions: 110x12mm
Tank AlarmsLow Level | Empty Tank Alarms
- Tank Alarm (Small): Adjustable to 500mm height with 3m pump tube & lead – 1 required per tank.
- Tank Alarm (Large): Adjustable to 1000mm height with 5m pump tube & lead – 1 required per tank.
Flow CellsTARAflow FLC-3 Flow Cell
Flow Cell for Membrane Sensor (High Temp). Rated @ 70°C | 800kPa
- Reagents | Buffer Solutions
-
pH BuffersORP VerificationCombination ph Buffer + ORP Calibration
AS4250
Combination pH Buffer Solution 4.01 + ORP Calibration Solution 250mV – 250 mls
AS7086
Combination pH Buffer Solution 7.01 + ORP Calibration Solution 86mV – 250 mls
Conductivity StandardElectrode CleaningAS9500
Electrode Cleaning Solution for Removal of Inorganic Deposits on Electrodes – 250ml
- Pumps
-
Peristaltic
Aquarius Technologies Peristaltic Pumps
Powerful, robust and reliable peristaltic dosing pumps.
- AP Peri1 : Peristaltic Pump rated @ 1.0 l/hr with 3pin plug
- AP Peri3 : Peristaltic Pump rated @ 3.0 l/hr with 3pin plug
PulseAthena AM3 Pulse Pump
Dosing pump with option of receiving external digital signal (pulse emitter water meter) or an analogue signal 4-20 mA. Manual flow regulation 0->100%.
- Flow Rate: 10 l/hr
- Max Pressure: 1,000 kPa
- Strokes/Min: 300
- Power Consumption: 40 watt
- Weight: 4Kg
- IP Rating: IP65
Athena AM4 Pulse Pump
Dosing pump with option of receiving external digital signal (pulse emitter water meter) or an analogue signal 4-20 mA. Manual flow regulation 0->100%.
- Flow Rate: 20 l/hr
- Max Pressure: 500 kPa
- Strokes/Min: 300
- Power Consumption: 40 watt
- Weight: 4Kg
- IP Rating: IP65
Olimpia Pulse Pumps
Variable + impulse electromagnetic dosing pumps.
- Olimpia OL.BB : rated 2.0L/h @ 700kPa | IP65
- Olimpia OL.BD : rated 5.0L/h @ 500kPa | IP65
- Solenoids | Relays
-
Solenoids
CO2 Regulator with 240VAC Solenoid Control
- 0-35 Lit/min CO2 Regulator
- Dual Gauges – Tank | Outlet Pressure
- High Quality Gas Solenoid with AU 240VAC plug
- Brass Fittings
- Barbed Brass CO2 Outlet
- Water Meters
-
Turbine Impulse Water Meters
Turbine Water Meters with Pulse Emitter (Reed Switch). Available in various sizes.
- RH1 Water Meter : Hot | Cold 15mm – Max Flow 5m3/h, 4 lmp/L
- RH2 Water Meter : Hot | Cold 20mm – Max Flow 5m3/h, 4 lmp/L
- RH3 Water Meter : Hot | Cold 25mm – Max Flow 7m3/h, 4 lmp/L
- RH4 Water Meter : Hot | Cold 40mm – Max Flow 20m3/h, 4 lmp/L
- RH5 Water Meter : Hot | Cold 50mm – Max Flow 30m3/h, 4 lmp/L
- Brominators
-
Brominators
Pressure Rated Feeders for the Controlled Dissolution of BCDMH – Bromine Tablets or Briquettes 12kg | 25kg | 100kg capacity.
- BCD12 : 12kg capacity rated to 350 kPa. Internal manifold designed for erosion efficiency. *Requires 15mm Solenoid.
- BCD25 : 25kg capacity rated to 350 kPa. Internal manifold designed for erosion efficiency. *Requires 20mm Solenoid.
- BCD100 : 100kg capacity rated to 350 kPa. Internal manifold designed for erosion efficiency. *Requires 25mm Solenoid.
- Web | Network Connectivity
-
Cellular Modem | SIM Web Access
- Modem 4G 850 : Web communication bundle with 4G modem (Add Web Access). *Ultima models only.
- Modem 4G 900 : 4G modem – 900mhz to enable full web control capabilities | alarming – Overseas users only.
- Web Access : SIM Card and annual contract for using AquaReporter Web Portal (Cloud).
Wi-Fi | Ethernet- WiFi Adapter : WiFi adapter replacement. *Ultima models only.
- Ethernet Adapter : Ethernet adapter replacement. *Ultima models only.
Ultima • BMS | Modbus • Board- BMS Board : PCB card to convert 8 signals to 4-20mA for BMS systems. *Ultima models only.
- Modbus Board : PCB card to enable Modbus capabilities to BMS|DDC systems. *Ultima models only.
Call Us To Customise Your Model
Our professional and highly experienced staff will be available to process your enquiries or provide free consultancy to your water treatment projects.